Two metals that should never be used together without protection are those that sit far apart on the galvanic series, for example, aluminium paired with copper, or zinc paired with stainless steel. When dissimilar metals come into direct contact in the presence of an electrolyte (such as seawater or moisture), an electrochemical reaction called galvanic corrosion begins, and the less noble metal deteriorates rapidly. The sections below unpack exactly how this works, which combinations are most damaging, and how to protect your installations.
What happens when incompatible metals touch each other?
When two dissimilar metals touch in the presence of moisture or an electrolyte, an electrical current flows between them. The less noble metal acts as the anode and begins to corrode, while the more noble metal acts as the cathode and remains protected. This process is called galvanic corrosion, and it can cause significant structural damage far faster than ordinary rust or oxidation.
The electrolyte is the key enabler. In dry indoor conditions, two dissimilar metals can often sit in contact without any meaningful reaction. But introduce seawater, condensation, or even humid air, and the circuit is complete. For anyone working in maritime, offshore, or coastal industrial environments, this distinction is critical: the environment practically guarantees the presence of an electrolyte at all times.
The speed and severity of the corrosion depend on three factors: how far apart the two metals are on the galvanic series, the surface area ratio between them, and the conductivity of the electrolyte. Seawater, being highly conductive, accelerates galvanic corrosion considerably compared to fresh water or mild humidity.
What is the galvanic series and how does it identify metal compatibility?
The galvanic series is a ranking of metals and alloys ordered by their electrochemical potential, in other words, how readily they give up electrons in a given environment. Metals at the active (or anodic) end of the series corrode preferentially, while metals at the noble (or cathodic) end resist corrosion. The greater the distance between two metals on this scale, the more aggressive the galvanic reaction will be when they are paired.
At the active end of the series you find metals like magnesium, zinc, and aluminium. Moving toward the noble end, you encounter copper, bronze, and stainless steel. Precious metals like titanium and gold sit at the most noble extreme. A practical rule of thumb: if two metals are close together on the galvanic series, they can often be used in contact with relatively low risk. If they are far apart, isolation is essential.
It is worth noting that the galvanic series is not a single fixed list: the ranking can shift slightly depending on the specific electrolyte involved. The series measured in seawater, which is the most relevant reference for marine and offshore applications, can differ from rankings measured in fresh water or industrial fluids. Always use a seawater-specific galvanic series when specifying materials for marine environments.
Need advice on your material selection?
Which alloy, size, or finish is right for your project?
From stainless steel to copper, brass, and aluminium — ask your question and our specialists will advise you free of charge on the right choice.
Ask your steel question →Which specific metal combinations cause the most damage?
The most damaging metal combinations are those that pair metals from opposite ends of the galvanic series. In marine and industrial contexts, the following pairings are known to cause rapid and severe corrosion:
- Aluminium and copper: One of the most aggressive combinations. Copper is significantly more noble than aluminium, causing aluminium to corrode quickly when the two are in contact with seawater.
- Steel and copper: Common in plumbing and structural applications, this pairing accelerates corrosion of the steel component.
- Zinc and stainless steel: Zinc corrodes rapidly when paired with stainless steel in a conductive environment, though this is sometimes used intentionally in sacrificial anode systems.
- Aluminium and stainless steel: Frequently encountered in offshore structures and vessel fittings, this combination can cause rapid aluminium degradation if not properly isolated.
- Magnesium and most other metals: Magnesium sits at the most active end of the galvanic series and will corrode aggressively when paired with nearly any other common structural metal.
In practice, the combinations involving copper and aluminium, or stainless steel and carbon steel in direct contact, are the ones most frequently responsible for unexpected corrosion failures in maritime and offshore structures.
Does the surface area ratio between metals affect corrosion speed?
Yes, the surface area ratio between the two metals has a significant effect on how fast galvanic corrosion progresses. A small anode (the less noble metal) connected to a large cathode (the more noble metal) is the worst possible scenario: the small anodic area must supply current to a large cathodic surface, causing it to corrode extremely quickly. The reverse situation, a large anode and small cathode, produces a much slower and more manageable reaction.
This principle has direct practical implications. Using a small stainless steel bolt to fasten aluminium plates, for example, is far less damaging than using a small aluminium rivet to join stainless steel sheets. In the first case, the large aluminium surface corrodes slowly. In the second, the tiny aluminium rivet deteriorates rapidly and the joint fails.
For procurement and engineering teams specifying marine steel products, this means that material selection cannot be made in isolation: the geometry of the assembly matters just as much as the choice of metals. A technically correct material specification can still lead to premature failure if the area ratios are unfavourable.
How can you safely use dissimilar metals together?
Dissimilar metals can be used safely together by preventing direct metal-to-metal contact, controlling the electrolyte, or intentionally managing the galvanic reaction. The most common and reliable approaches include the following:
- Electrical isolation: Use non-conductive gaskets, washers, sleeves, or coatings between the two metals to break the electrical circuit. This is the most effective method when properly applied.
- Protective coatings: Apply paint, epoxy, or other barrier coatings to the cathodic metal (the more noble one) to reduce the surface area driving the reaction. Coating the anodic metal alone is less effective and can actually worsen localised corrosion if the coating is breached.
- Sacrificial anodes: Attach a third, more active metal (typically zinc or aluminium alloy) to the assembly. This metal corrodes preferentially, protecting both structural metals. This approach is widely used on vessel hulls and offshore platforms.
- Metal selection: Where possible, choose metals that are close together on the galvanic series. For example, pairing bronze with copper, or using 316 stainless steel with duplex stainless steel, significantly reduces galvanic risk.
- Moisture control: In enclosed or indoor structures, eliminating the electrolyte by keeping the joint dry removes the driving force for galvanic corrosion entirely.
In practice, most robust designs use a combination of these methods rather than relying on a single approach.
What metal pairings are safe to use in marine environments?
In marine environments, safe metal pairings are those where both metals sit close together on the seawater galvanic series, minimising the electrochemical potential difference between them. The following combinations are generally considered low-risk for marine applications:
- Copper and bronze: Both are copper-based alloys and sit close on the galvanic series, making them a reliable pairing for fittings, valves, and pipework.
- Copper and brass: Similar reasoning applies: brass is a copper-zinc alloy, and the two are galvanically compatible in most marine conditions.
- 316 stainless steel and duplex stainless steel: Both are highly corrosion-resistant and electrochemically close, making them suitable for structural and piping applications offshore.
- Carbon steel with sacrificial zinc anodes: Not a passive safe pairing, but a managed one, widely used on hulls and submerged structures where the zinc corrodes intentionally to protect the steel.
- Monel and copper-nickel alloys: Both are commonly used in seawater piping systems and are galvanically compatible with each other.
When specifying materials for marine or offshore environments, always cross-reference your intended pairings against a seawater galvanic series and factor in the geometry of the assembly. When in doubt, isolation between metals is always the safer default.
How Marine Steel helps you avoid costly metal compatibility mistakes
Galvanic corrosion is one of the most preventable causes of premature material failure, but only if the right metals are specified from the start. That is where we come in. At Marine Steel, we stock a broad range of ferrous and non-ferrous metals from our warehouses in Rotterdam and Houston, and we actively help clients choose compatible materials for their specific application.
- Extensive stock of steel, stainless steel, copper, brass, bronze, aluminium, zinc, and more, all from a single source
- Expert advice on material compatibility for marine, offshore, and industrial environments
- Pipes, plates, fittings, flanges, and profiles available in the right grades and dimensions
- Cut-to-size and custom fabrication services so materials arrive ready to use
- 24/7 availability and fast delivery for time-critical operations
You do not need to figure out the galvanic series on your own. Tell us what you are building, where it will be installed, and what metals are already in the assembly, and we will advise on the safest, most cost-effective combination. Get in touch with our team and we will get back to you quickly with a complete solution.
Frequently Asked Questions
How do I know if galvanic corrosion is already occurring in my existing installation?
Early signs of galvanic corrosion include white or rust-coloured staining around metal joints, pitting or flaking on one of the two metals in contact, and fasteners or fittings that have deteriorated faster than expected. The less noble metal will always show the damage first, so inspect that component closely — for example, if aluminium and stainless steel are paired, check the aluminium for pitting or surface degradation. If you suspect ongoing galvanic corrosion, a marine materials specialist can assess the assembly and recommend whether isolation, sacrificial anodes, or replacement is the most practical fix.
Can protective coatings alone fully prevent galvanic corrosion in a harsh offshore environment?
Coatings can be highly effective, but they should not be relied upon as the sole line of defence in offshore or marine environments where mechanical wear, UV exposure, and constant moisture are present. Even a small scratch or holiday (pinhole) in the coating on the anodic metal can concentrate corrosion at that single point, accelerating localised damage significantly. Best practice is to combine coatings with physical isolation (non-conductive gaskets or sleeves) and, where appropriate, sacrificial anodes — a layered approach that accounts for the inevitable degradation of any single protective measure over time.
What is the most common mistake engineers make when specifying metals for marine assemblies?
The most frequent mistake is selecting metals based on their individual corrosion resistance without considering how they will interact with the other metals already present in the assembly. A metal like 316 stainless steel is highly corrosion-resistant on its own, but placing it in direct contact with aluminium in a seawater environment will cause the aluminium to deteriorate rapidly. Always evaluate the full assembly — including fasteners, brackets, and fittings — against a seawater galvanic series, and pay close attention to surface area ratios, since an unfavourable ratio can cause failure even between metals that are relatively close on the series.
How often should sacrificial anodes be inspected and replaced in a marine structure?
As a general rule, sacrificial anodes should be inspected at least every 12 months for offshore structures and every haul-out cycle for vessels, though high-current environments or heavily contaminated seawater may require more frequent checks. An anode that has been consumed by more than 50% of its original mass should be replaced promptly — waiting until it is fully depleted leaves the protected structure exposed. The replacement schedule should also be reviewed if the structure undergoes modifications that change the total metal surface area or introduce new dissimilar metal pairings.
Does galvanic corrosion occur in freshwater or only in saltwater environments?
Galvanic corrosion can occur in freshwater, but it progresses much more slowly than in seawater because freshwater has significantly lower electrical conductivity, which limits the current flow between the two metals. Seawater’s high salt content makes it an excellent electrolyte, which is why galvanic corrosion is such a critical concern in marine and offshore applications. That said, freshwater systems — particularly those in industrial plants, cooling circuits, or coastal facilities with condensation — should not be treated as risk-free: the corrosion is slower, but over a long service life it can still cause meaningful structural damage if incompatible metals are left in direct contact.
Are there any non-metallic fastener options that can help eliminate galvanic corrosion at joints?
Yes — non-metallic fasteners made from materials such as nylon, PTFE, fibreglass-reinforced polymer (FRP), or other engineering plastics are a practical solution for low-load connections where breaking the electrical circuit is the priority. These materials introduce no galvanic potential of their own and are highly resistant to seawater and chemical environments. For structural joints that require the mechanical strength of metal fasteners, the preferred approach is to use metal fasteners with non-conductive isolation sleeves and washers, which maintain load-bearing capacity while preventing direct metal-to-metal contact.
If I need to use aluminium and stainless steel together, what is the safest way to do it?
The safest approach when aluminium and stainless steel must be used together is to combine electrical isolation with favourable area ratios. Use non-conductive isolation bushings, sleeves, and washers to prevent any direct contact between the two metals, and apply a barrier coating to the stainless steel surfaces nearest the joint. Ensure that the aluminium component has a significantly larger surface area than the stainless steel fasteners or fittings — this slows any residual corrosion to a manageable rate even if the isolation is imperfect. For critical structural applications in seawater environments, adding zinc or aluminium alloy sacrificial anodes to the assembly provides an additional layer of protection.